Skip to product information
1 of 6

Venus GX for monitoring and displaying Victron devices

Venus GX for monitoring and displaying Victron devices

Regular price €233,05
Regular price Sale price €233,05
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity

The Venus GX offers intuitive operation and monitoring of all Victron power systems. The list of Victron products that can be connected to it includes almost all VICTRON products: inverters, Multis, Quattros, MPPT solar chargers, BMV, Lynx Ion + Shunt and other devices.

Areas of application:

The Venus GX can be used in various applications.

  • For monitoring / controlling connected components in the local network (without internet connection via WLAN or network cable)
  • For monitoring / controlling energy storage systems (ESS), internet connection may be required
  • In RVs for checking fill levels, temperature(s), available battery capacity, solar power, etc. (GSM router required)
  • In boats, garden sheds and many other locations provided a GSM connection (router) is available.

VRM Online Portal

If the Venus GX is connected to the internet, all measurement data can be forwarded to the free VICTRON website for remote monitoring: the VRM Online Portal

Remote Console on the VRM

Setup and monitoring are done via the Remote Console. Either via the VRM, via the built-in WiFi access point or via the local LAN/WiFi network. (e.g. via your own router or via a commercially available GSM router. The VRM app is available for free in the Google Play Store or Apple App Store or can be accessed via an internet browser.

Automatic Generator Start/Stop

An extremely flexible start/stop system. Uses charge, voltage, load and other parameters. Specific settings for quiet times and optionally a monthly test run can be set.

The Heart of the ESS – Energy Storage System

The Venus GX is the energy manager in an ESS. More information in the ESS manual: https://www.victronenergy.com/live/ess:design-installation-manual

Data Logging

If the system is connected to the internet, all data is sent to the VRM portal. If there is no internet connection, the Venus GX stores the data internally for up to 48 hours. By inserting a Micro-SD card or a USB stick, even more data can be stored. These files can be uploaded to the VRM portal or converted for analysis offline with the VictronConnect App.

Supported Products

  • Multis and Quattros, including split-phase and three-phase systems. Monitoring and control (on/off and current limiter). Configuration changes are possible (remotely via internet only, not without internet connection).
  • EasySolar 1600VA
  • BlueSolar MPPT Solar Chargers with a VE.Direct Port.
  • BlueSolar MPPT 150/70 and MPPT 150/85 with VE.Can Port. If several
  • BlueSolar MPPTs with VE.Can are used in parallel, all information is combined into one. Please also see our blog post on synchronizing multiple MPPT 150/70 solar chargers.
  • BMV-700 family devices can be connected directly to the VE.Direct ports on the Venus GX. Use the VE.Direct cable for this.
  • BMV-7xx family devices can be connected to the VE.Direct ports on the Venus GX. An additional cable is required.
  • Lynx Ion + Shunt
  • Lynx Ion BMS
  • Lynx Shunt VE.Can
  • Skylla-i Battery Chargers
    Inexpensive tank sensors (0 - 180 Ohm), or with US tank senders (240 - 30 Ohm)
  • A USB GPS can be connected to the USB port. The data is sent to the VRM portal for traceability. The current position is then displayed on the map on the VRM.
  • Fronius PV inverters
  • If more than two VE.Direct products need to be connected, a USB port can be used.

Internet Connection

The Venus GX can be connected to the internet with an Ethernet cable and via Wi-Fi. The Venus GX does not have an internal cellular modem: there is no slot for a SIM card. Instead, use a commercially available GPRS or 3G router. Please see the blog post about 3G routers.

Tank Level Sensor Inputs

The tank level sensor inputs are resistive: connect them to a resistive tank sender. Such tank senders are not offered by Victron. The tank level sensor ports can each be configured to work with European tank senders (0 - 180 Ohm) or with US tank senders (240 - 30 Ohm).

Further Highlights

  • The Venus GX can automatically update itself via the internet when a new software version is available.
  • Multiple languages: English, Czech, German, Spanish, French, Italian, Dutch, Russian, Swedish, Turkish, Chinese, Arabic.
  • Use the Venus GX as a Modbus-TCP Gateway to all connected Victron products. Please refer to the Modbus-TCP FAQ for more information.

Scope of delivery:

  • Venus GX
  • Connectors for Venus GX
  • Access code for VRM portal
  • DC cable for power supply incl. fuse holder and fuse.
  • Termination resistors for Ve.can network connections
Versandinfos

Bitte beachte, dass einige unserer Produkte außergewöhnlich groß, schwer oder zerbrechlich sind. Abhängig von den Versandanforderungen nutzen wir Sperrgut- oder auch Speditionsversand sowie unterschiedliche Versanddienstleister. In Kombination mit der Versandversicherung können hierdurch höhere Versandkosten entstehen. Bei Fragen zum Versand, nimm gerne Kontakt zu uns auf.

Technical Data

SKU:97345

View full details